Section 4: Indoor installations
consolidated text (as at 2013, amended since). juris shows the text as it was consolidated; it does not confirm that this is the law in force today.
4. Indoor installations
(1) Access shall always be as easy as practicably possible, and stores shall
normally be placed at ground level with doors and gates without any steps to
facilitate internal transport.
(2) Depending on the properties of the chemicals, the doors shall give access directly to the open, for instance when storing highly flammable or volatile
chemicals.
(3) The following precautions shall be taken—
(a) the temperature of the store shall not exceed 40 degrees centigrade
and cooling shall be provided if necessary;
(b) necessary equipment to keep the humidity of the store within specific
allowed range and for drying the air shall be provided;
(c) sufficient natural or adequate mechanical ventilation shall be provided
to prevent the formation of dangerous vapour-concentrations or
odour;
(d) if loss of containment may be expected and the vapours are toxic or
potent to health, the ventilation shall be started automatically using a
suitable detector or operated from outside;
(e) lighting devices according to standards shall be installed depending
on operations to be carried out.